Before requesting a microwave generator quote, gather as much of the following information as possible:

Application
  • What is the microwave energy being used for?
  • What material or process is involved?
  • Is the application heating, drying, plasma generation, CVD, or another process?
Frequency
  • Is 915 MHz, 2450 MHz, or another frequency required?
  • Is the frequency determined by existing equipment?
Power
  • What microwave output power is required?
  • What power-adjustment range is needed?
  • Will one generator or multiple generators be required?
Configuration
  • Integrated or remote magnetron head?
  • How much installation space is available?
  • How close will the generator be to the applicator?
Cooling
  • Air or water cooling?
  • What cooling-water capacity is available?
Electrical
  • What line voltage is available?
  • What electrical service is available at the installation?
Power Delivery
  • What waveguide size is required?
  • Is there an existing waveguide system?
  • Are isolators, circulators, tuners, loads, or directional couplers required?
Controls
  • Local or remote control?
  • Analog, digital, or PLC interface?
  • Is forward and reflected power monitoring required?
Integration
  • Is this a new system or a replacement generator?
  • Does the generator need to interface with existing equipment?
  • Are there dimensional or mechanical restrictions?
Operating Environment
  • What ambient conditions will the generator experience?
  • Is continuous operation required?
  • Are there special environmental or regulatory requirements?
Providing this information can help an experienced microwave engineer identify the appropriate generator and supporting components for your application.